CVE-2013-2806 Information
Description
Rockwell Automation RSLinx Enterprise Software (LogReceiver.exe) CPR9 CPR9-SR1 CPR9-SR2 CPR9-SR3 CPR9-SR4 CPR9-SR5 CPR9-SR5.1 and CPR9-SR6 does not handle input correctly and results in a logic error if it calculates an incorrect value for the “End of Current Record” field. By sending a datagram to the service over Port 4444/UDP with the “Record Data Size” field modified to a specifically oversized value the service will calculate an undersized value for the “Total Record Size.” Then the service will calculate an incorrect value for the “End of Current Record” field causing access violations that lead to a service crash. The service can be recovered with a manual reboot. The patches and details pertaining to these vulnerabilities can be found at the following Rockwell Automation security advisory link (login is required): https://rockwellautomation.custhelp.com/app/answers/detail/a_id/537599
CVSS Vector
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Reference
https://ics-cert.us-cert.gov/advisories/ICSA-13-095-02
Attack Complexity
LOW
Privileges Required
NONE
User Interaction Required
NONE
Scope
NONE
Confidentiality Impact
UNCHANGED
Integrity Impact
NONE
Availability Impact
NONE
Base Score
HIGH
Base Severity
7.5
Share on: