CVE-2017-6780 Information

Description

A vulnerability in the TCP throttling process for Cisco IoT Field Network Director (IoT-FND) could allow an unauthenticated remote attacker to cause the system to consume additional memory eventually forcing the device to restart aka Memory Exhaustion. The vulnerability is due to insufficient rate-limiting protection. An attacker could exploit this vulnerability by sending a high rate of TCP packets to a specific group of open listening ports on a targeted device. An exploit could allow the attacker to cause the system to consume additional memory. If enough available memory is consumed the system will restart creating a temporary denial of service (DoS) condition. The DoS condition will end after the device has finished the restart process. This vulnerability affects the following Cisco products: Connected Grid Network Management System if running a software release prior to IoT-FND Release 4.0; IoT Field Network Director if running a software release prior to IoT-FND Release 4.0. Cisco Bug IDs: CSCvc77164.

CVSS Vector

CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Reference

https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20170906-fnd http://www.securityfocus.com/bid/100641

Attack Complexity

LOW

Privileges Required

NONE

User Interaction Required

NONE

Scope

NONE

Confidentiality Impact

UNCHANGED

Integrity Impact

NONE

Availability Impact

NONE

Base Score

HIGH

Base Severity

7.5

Share on: