CVE-2018-4861 Information

Description

A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp) could potentially read and download arbitrary files from the device’s file system. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

CVSS Vector

CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N

Reference

https://cert-portal.siemens.com/productcert/pdf/ssa-977428.pdf

Attack Complexity

LOW

Privileges Required

HIGH

User Interaction Required

HIGH

Scope

NONE

Confidentiality Impact

UNCHANGED

Integrity Impact

HIGH

Availability Impact

NONE

Base Score

NONE

Base Severity

4.9

Share on: