Description
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5) SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). Devices create a new unique key upon factory reset except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
CVSS Vector
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
Reference
https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02
Attack Complexity
HIGH
Privileges Required
NONE
User Interaction Required
NONE
Scope
NONE
Confidentiality Impact
UNCHANGED
Integrity Impact
HIGH
Availability Impact
NONE
Base Score
NONE
Base Severity
5.9