Description
Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version < 2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. The recommended solution is to update the firmware to a version >= 2.2.0 as soon as possible. (available in SICK Support Portal)