CVE-2024-10130 Information
Nov 01, 2024
cve
Description
A vulnerability classified as critical was found in Tenda AC8 16.03.34.06. This vulnerability affects the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Reference
https://vuldb.com/?id.280918 https://vuldb.com/?ctiid.280918 https://vuldb.com/?submit.422141 https://github.com/JohenanLi/router_vuls/blob/main/ac8v4/FUN_004a8838.md https://www.tenda.com.cn/
Attack Complexity
LOW
Privileges Required
LOW
User Interaction Required
LOW
Scope
NONE
Confidentiality Impact
UNCHANGED
Integrity Impact
HIGH
Availability Impact
HIGH
Base Score
HIGH
Base Severity
8.8
Share on: