CVE-2025-30645 Information
Description
A NULL Pointer Dereference vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker causing specific valid control traffic to be sent out of a Dual-Stack (DS) Lite tunnel to crash the flowd process resulting in a Denial of Service (DoS). Continuous triggering of specific control traffic will create a sustained Denial of Service (DoS) condition.
On all SRX platforms when specific valid control traffic needs to be sent out of a DS-Lite tunnel a segmentation fault occurs within the flowd process resulting in a network outage until the flowd process restarts.
This issue affects Junos OS on SRX Series: All versions before 21.2R3-S9 from 21.4 before 21.4R3-S9 from 22.2 before 22.2R3-S5 from 22.4 before 22.4R3-S6 from 23.2 before 23.2R2-S3 from 23.4 before 23.4R2.
CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Reference
https://supportportal.juniper.net/JSA96455
Attack Complexity
LOW
Privileges Required
NONE
User Interaction Required
NONE
Scope
NONE
Confidentiality Impact
UNCHANGED
Integrity Impact
NONE
Availability Impact
NONE
Base Score
HIGH
Base Severity
7.5
Share on: