Description

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used ‘UnlockProject’ method. This could allow an authenticated remote attacker to bypass authorization controls to read from and write to the application’s database and execute code with \NT AUTHORITY\NetworkService\ permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

CVSS Vector

CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Reference

https://cert-portal.siemens.com/productcert/html/ssa-443402.html

Attack Complexity

LOW

Privileges Required

LOW

User Interaction Required

LOW

Scope

NONE

Confidentiality Impact

UNCHANGED

Integrity Impact

HIGH

Availability Impact

HIGH

Base Score

HIGH

Base Severity

8.8